UN38.3 Testing for Lithium Batteries

UN 38.3 Testing as the Basis for the Safe Transport of Lithium Batteries

Lithium-ion, lithium-metal, and certain sodium-ion batteries are subject to dangerous goods transport requirements. One of the key conditions for preparing cells and batteries for transport is compliance with the testing requirements set out in the UN Manual of Tests and Criteria, Part III, Subsection 38.3.

At the DLP laboratory, we conduct UN 38.3 testing for cells and batteries, tailoring the scope of testing to the specific product type and configuration. A positive test result provides the basis for preparing the documentation required for the transport of batteries in accordance with the applicable regulations.

What is Section 38.3 of the UN Manual and why does your battery need it?

UN 38.3 is a set of safety tests required for types of lithium cells and batteries, and now also for certain sodium-ion batteries, intended for transport. The tests simulate the conditions and stresses that a battery may be exposed to during transport and confirm whether a given type meets the requirements set out in the UN Manual of Tests and Criteria.

A positive test result provides the basis for preparing the UN 38.3 Test Summary, a document required within the transport chain and made available for the tested cell or battery type.

It is also important to note that UN 38.3 compliance applies to a specific design type. Significant changes to the battery design or parameters may require reassessment and appropriate testing. Therefore, at DLP, before starting a project, we verify the battery design and define the scope of testing according to the specific product.

Testing Procedures and Pass Criteria: The 8 Tests of the UN38.3 Standard

During transport, cells and batteries are exposed to changes in pressure and temperature, vibrations, and mechanical shocks, among other conditions. UN 38.3 testing reproduces these conditions in a controlled laboratory environment and makes it possible to verify the safety of a specific type during transport.

Section 38.3 covers eight types of tests, designated T.1–T.8. However, not every battery is subject to all eight tests. The required scope depends on the design and type of the product being tested. Therefore, before starting a project at DLP, we determine the appropriate test sequence and the required number of test samples.

Table 1: Scope of testing and pass criteria according to UN 38.3

Test

Test parameters and procedure (in accordance with 38.3.4)

Pass criteria

T.1: Altitude simulation

Storage at a pressure of 11.6 kPa or lower for a minimum of 6 hours at ambient temperature (20 ± 5 °C). Simulation of airplane cargo hold conditions.

No leakage (mass loss exceeding the limits in Table 38.3.1), no venting, no disassembly, no rupture, and no fire. Open circuit voltage of a minimum of 90% of its initial voltage.

T.2: Thermal test

Extreme temperature shocks: a minimum of 6 hours at 72 ± 2 °C, followed by a minimum of 6 hours at -40 ± 2 °C. Maximum transfer time: 30 min. 10 cycles. Large batteries: minimum exposure of 12 hours.

No leakage, no venting, no disassembly, no rupture, and no fire. Open circuit voltage after the test is a minimum of 90% of its initial voltage.

T.3: Vibration

Sinusoidal waveform, logarithmic sweep (7 Hz - 200 Hz - 7 Hz) over 15 minutes. Repeated for 3 hours for each of the 3 axes.

No leakage, no venting, no disassembly, no rupture, and no fire. Open circuit voltage immediately after the test is a minimum of 90%.

T.4: Shock

Half-sine wave. Small batteries: 150gn for 6 ms. Large batteries: 50gn for 11 ms. A total of 18 shocks (3 for each axis and direction).

No leakage, no venting, no disassembly, no rupture, and no fire. Open circuit voltage is a minimum of 90%.

T.5: External short circuit

Sample heated (casing to 57 ± 4 °C). Subjected to a short circuit with a total resistance of less than 0.1 ohm. The short circuit condition is maintained for at least 1 hour after the cell or battery case temperature returns to 57 ± 4 °C, or, in the case of large batteries, decreases by half of the maximum temperature increase observed during the test and remains below this value.

Maximum external temperature of 170°C. No disassembly, no rupture, and no fire during the test and for 6 hours after it.

T.6: Impact / Crush

Impact (cylindrical cells with a minimum diameter of 18.0 mm): A 9.1 kg mass dropped from 61 cm onto a 15.8 mm bar.

Crush (other cells): Crushing until reaching 13 kN, a voltage drop of 100 mV, or 50% deformation.

Maximum external temperature of 170°C. No disassembly, no rupture, and no fire during the test and for 6 hours after it.

T.7: Overcharge

(Rechargeable batteries). Application of a current equal to twice the maximum recommended current. Duration: 24 hours.

No disassembly and no fire during the test and within 7 days after its completion.

T.8: Forced discharge

Forced discharge at a current equal to the maximum discharge current.

No disassembly and no fire during the test and within 7 days after its completion.

*The voltage drop requirement does not apply to cells and batteries tested in a fully discharged state.

How many samples are required for UN 38.3 testing?

The number of samples required for UN 38.3 testing depends on the type and design of the product, including whether a single cell, a battery, or a complete battery pack is being tested, as well as whether the product is rechargeable or non-rechargeable. The parameters of the type being tested and the scope of tests required are also relevant. The UN Manual of Tests and Criteria specifies different testing requirements for different types of cells and batteries.

Example breakdown for rechargeable batteries:

  • Cells and single-cell batteries: In total, we require the delivery of several dozen units to be divided among tests T.1-T.5 (10 pcs), T.6 (10 pcs), and T.8 (20 pcs) in various states of charge.

  • Small batteries up to 12 kg: Typically, 8 units subjected to the T.1-T.5 sequence are sufficient (half new, half after 25 cycles), which then proceed to test T.7.

  • Large batteries over 12 kg: Due to their dimensions, the standard requires a smaller quantity – typically 4 units for the T.1-T.5 sequence and test T.7.

*This is a simplified model. We will prepare the exact material specification for sample shipping for you during a free consultation.

Batteries integrated into equipment

Is the battery permanently integrated into the equipment, meaning that removing it would require interference with the product’s design? In certain cases, UN 38.3 allows the applicable tests to be performed on a cell or battery as an integral part of the equipment, provided that it is transported only with the battery installed in the equipment.

Before starting testing at DLP, we analyse the product design and the way it will be transported. We then determine whether testing the battery within the equipment is applicable and define the required scope of testing.

Move smoothly through the UN 38.3 testing process

Proper preparation of the battery and test samples helps ensure a smoother testing process. At DLP, we help define the required scope of UN 38.3 testing and prepare the project to minimise the risk of additional testing and delays.

FAQ: UN 38.3 Testing and Test Report

What types of batteries are subject to mandatory UN 38.3 testing?

According to the UN Model Regulations, all lithium-ion, lithium-metal, and the increasingly popular sodium-ion cells and batteries are subject to testing. They are classified as Class 9 dangerous goods, which is why their air, sea, and road transport requires prior safety validation.

How many sample units do I need to provide to the DLP-Poland laboratory?

The number of samples depends on whether we are testing a single cell or a finished battery, as well as the mass of the product itself. Typically, for small batteries (up to 12 kg), we need 8 units. In the case of large batteries (over 12 kg), the standard allows this number to be reduced to 4 units. We will prepare the exact specification for you during a free consultation.

What are the consequences of not having a valid UN 38.3 test report?

The lack of a Test Summary document means your batteries will be blocked in transit. Carriers (IATA, IMDG, ADR) will not accept the cargo on board, resulting in delays, frozen capital, and serious problems with delivering equipment to your business partners.

My equipment has an integrated battery. Do I need to disassemble it for testing?

There is no need for that. According to section 38.3.2.1 of the UN Manual, cells or batteries that form an integral part of the equipment can be tested directly inside the device. Our engineers will select a procedure to avoid unnecessary disassembly of your product.

What stages does the UN 38.3 testing procedure consist of?

The standard includes up to 8 rigorous tests (from T.1 to T.8) that simulate the harshest logistical conditions. These include altitude simulation (cargo hold pressure), extreme thermal shocks, vibrations, shocks, external short circuits, as well as mechanical and electrical tests (e.g., overcharge). Tests T.1 through T.5 are performed sequentially on the same samples.

Do I have to retest the battery if its weight or design changes?

Yes. UN regulations require revalidation after any significant design change. This includes a change in the mass of primary batteries by more than 20%, a change in the nominal energy of rechargeable batteries by more than 20%, or any modifications to key components affecting safety. It is then treated as a "new type" of product.

an abstract photo of a curved building with a blue sky in the background

Expert knowledge. Practical guidance. Key regulatory updates.

Subscribe to our newsletter and stay up to date with practical insights on laboratory testing, certification, type approval, product compliance, and regulatory requirements across the European market.

DLP Sp. z o.o. is the controller of your personal data. Your data will be processed for the purpose of delivering our newsletter. You may withdraw your consent at any time. For detailed information on how we process your personal data, please refer to our Privacy Policy.

Contact

+48 32 49 44 305

© 2025 DLP SP. Z O.O.

office@dlp-poland.com

ul. G. Morcinka 7D, 43-417 Kaczyce

Company Registration Details

DLP Sp. z o.o.
TAX ID PL5482760314
KRS: 0001105711
Share Capital: 150 000, 00 zł